Assessment of wastewater characteristics and management system: A case study on Felege Hiwot compressive specialized hospital, Amhara region (Ethiopia)
This study focuses on characterizing the wastewater and evaluating the existing onsite sanitation infrastructure, with a particular emphasis on the fecal sludge management system (FSMS) at Felege Hiwote Referral Hospital, Ethiopia. Effluent samples were collected from the Emergency, Eye, Kidney, Medical, and Delivery departments and analyzed to assess critical parameters, including pH, turbidity, electrical conductivity, dissolved oxygen, chemical oxygen demand, total nitrogen, total phosphorus, total suspended solids, biological oxygen demand, and total dissolved solids. The findings reveal significant deviations from standard limits across departments, underscoring the need for improved wastewater management. pH ranged from 7.66 – 9, which falls within the acceptable range of 6 to 9. However, dissolved oxygen varying between 0.02 to 0.36 mg/L, chemical oxygen demand was reach up to 1072 mg/L. Total nitrogen and total phosphorus levels was reach up to 108 mg/L and 63 mg/L, respectively. TDS, total suspended solid, and turbidity was also measured as high as 3042 mg/L, 1678 mg/L and 6050 NTU. Biological oxygen demand levels were also alarmingly high, with values up to 825 mg/L. The wastewater analysis indicating oxygen depletion, the presence of high organic loads, overload of oxidizable matter, high load of nutrients, and excess solid maters. These finding highlight the urgent need for enhanced FSMS and the implementation of more effective onsite wastewater treatment systems within the hospital.